Electroretinograms before and after extraction of large intraocular iron foreign body

Purpose: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful.Observations: A 37-year-old man was kaiser copy stands injured by an iron fragment that penetrated into his left eye through the cornea.His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus.

B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye.Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts.Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed.

The decimal visual acuity improved to 1.2 two weeks later.The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye.

Conclusions and importance: We recommend that the physiology of the retina be assessed by recording ERGs altitude sunscreen with a skin-type electrode as soon as possible after a traumatic injury to the eye.Keywords: Electroretinography, Skin electrode, Intraocular foreign body, Pars plana vitrectomy.